SM-8
The MONTAGUE Company
4. Install the new pilot assembly, orifice and pilot
assembly bracket.
5. Connect the gas line to the back of pilot assembly.
NOTE: Make sure that the pipe joint compound or
pipe thread sealant that is being used is resistant
to the corrosive actions of liquefied petroleum gases.
6. Turn the main gas shutoff valve to the broiler to
the ON position.
WARNING
ALL GAS JOINTS DISTURBED DURING
SERVICING MUST BE CHECKED FOR LEAKS.
CHECK WITH A SOAP AND WATER SOLUTION
(BUBBLES). DO NOT USE AN OPEN FLAME.
7. Light pilot and adjust pilot valve.
8. Reinstall venturi cover, heat shield, insulation and
exterior top.
Figure 6. Pilot Assembly Connection
Figure 7. Pilot Assembly
MAIN BURNERS
The connection for the burners is accessed by removing
the venturi cover. The burners are accessed by
removing the grids and carriage. The burner valves are
accessed by removing the control panel cover.
CAUTION
Turn off the gas supply at the main shutoff
valve that is next to the broiler before
attempting to loosen any gas connections.
Burner Assembly, Orifice and Venturi
1. Remove the venturi cover as described in COVERS
AND PANELS.
2. Remove the ceramic radiants from each side of
the main burner to be replaced.
3. Loosen the set screw that attaches the main
burner to the venturi assembly.
4. Slide the main burner out of the broiler.
5. If the venturi or orifice is to be replaced, disconnect
the gas input to the venturi. Remove the gasket.
Replace the gasket every time the venturi or
burner is removed.
6. Loosen the lock nut so that the venturi can be
removed from the bracket.
Figure 8. Burner Pilot Assembly
7. Remove the orifice hex nut fitting from the venturi.
8. Remove the orifice from the hex nut fitting.
NOTE: Make sure that the pipe joint compound or
pipe thread sealant that is being used is resistant
to the corrosive actions of liquefied petroleum gases.